Maximum rated design tension (MRDT), kN | 4 | ||||
Crush, kN/cm | 0.3 | ||||
External strength member jacket diameter, mm | 5.0 | ||||
Fiber count, up to | 6 | 8 | 12 | 16 | 24 |
Cable jacket diameter, mm | 6.2 | 6.3 | 6.5 | 6.7 | 7.0 |
Maximum overall cable size, mm | 12.2 | 12.3 | 12.5 | 12.7 | 13.0 |
Cable weight, kg/km | 70.6 | 71.4 | 73.2 | 75.1 | 77.9 |
Maximum rated design tension (MRDT), kN | 6 | ||||
Crush, kN/cm | 0.3 | ||||
External strength member jacket diameter, mm | 5.6 | ||||
Fiber count, up to | 6 | 8 | 12 | 16 | 24 |
Cable jacket diameter, mm | 6.2 | 6.3 | 6.5 | 6.7 | 7.0 |
Maximum overall cable size, mm | 12.8 | 12.9 | 13.1 | 13.3 | 13.6 |
Cable weight, kg/km | 87.5 | 88.4 | 90.2 | 92.1 | 94.9 |
Maximum rated design tension (MRDT), kN | 9 | ||||
Crush, kN/cm | 0.3 | ||||
External strength member jacket diameter, mm | 6.2 | ||||
Fiber count, up to | 6 | 8 | 12 | 16 | 24 |
Cable jacket diameter, mm | 6.2 | 6.3 | 6.5 | 6.7 | 7.0 |
Maximum overall cable size, mm | 13.4 | 13.5 | 13.7 | 13.9 | 14.2 |
Cable weight, kg/km | 108.0 | 108.9 | 110.6 | 112.5 | 115.3 |
Maximum rated design tension (MRDT), kN | 12 | ||||
Crush, kN/cm | 0.3 | ||||
External strength member jacket diameter, mm | 6.8 | ||||
Fiber count, up to | 6 | 8 | 12 | 16 | 24 |
Cable jacket diameter, mm | 6.2 | 6.3 | 6.5 | 6.7 | 7.0 |
Maximum overall cable size, mm | 14.0 | 14.1 | 14.3 | 14.5 | 14.8 |
Cable weight, kg/km | 131.9 | 132.8 | 134.6 | 136.4 | 139.2 |
Operating temperature | -50°C … +70°C |
Installation temperature | -30°C … +50°C |
Transportation and storage temperature | -50°C … +70°C |
Minimum bending radius | 15 x cable diameter |
Design life | 25 years |